Our products

Bare & tin-plated copper busbars

Copper busbars in bare and tin-plated finishes for conductive links, switchgear and equipment connections. Define the cross section, edge profile, material condition and finish around your assembly requirements.

01 / SIZES & SELECTION

Choose the section, edges and working length.

These common flat-bar examples help structure an inquiry. State dimensions as thickness × width, then the length. A section size alone does not establish the current rating of an assembly.

The dimensions below are practical sourcing examples, not a confirmed stock list or manufacturing limit. Supply combinations and tolerances are confirmed for the selected grade, temper and order.

Form / dimensionCommon inquiry examplesSelection notes
Flat bar · thickness × width3 × 20, 3 × 25, 3 × 30 mmSmaller conductive links and fabricated blanks. Provide the required quantity, finished geometry and connection layout.
Flat bar · thickness × width5 × 20, 5 × 30, 5 × 40, 5 × 50 mmInquiries for equipment links and distribution parts; agree the material condition, contact faces and processing allowance.
Flat bar · thickness × width8 × 40, 8 × 50, 8 × 60, 8 × 80 mmDefine edge profile, straightness and hole or bend drawings. Suitability is assessed within the complete electrical design.
Flat bar · thickness × width10 × 50, 10 × 60, 10 × 80, 10 × 100 mmLarger-section sourcing examples. Specify finished tolerances, handling limits and whether dimensions apply before or after plating.
Corner and edge geometryRounded corner / rounded edge, radius by drawingSpecify the radius or profile rather than relying on a photo. Edge geometry affects fit, forming and the required surface condition.
Length, holes and bends3,000 mm inquiry reference; cut lengths and geometry by drawingInclude hole diameters, centres, slots, bend angles and radii, drawing revision and pieces per item.

Plating and final dimensions

State whether dimensions and fits apply to the copper substrate or the finished plated component. Identify critical contact areas, masking needs and coating coverage on cut edges and holes.

Current rating belongs to the assembly

Operating current depends on thermal conditions, bar arrangement, joints, enclosure and design limits. Supply the drawing and requirements; the size table is not an ampacity chart or an assembly certification.

Define the geometry your assembly needs

  • Agree thickness, width, length, straightness, edge radius and any tighter finished-part tolerances against the selected standard or drawing.
  • Identify hole position, slot size, bend radius, end finish, burr limits and contact-face flatness where applicable.
  • For tinned orders, agree coating method and thickness, coverage, appearance and the required inspection evidence before production.
02 / MATERIAL & TEMPER

Choose the grade for the job.

01

C11000 / Cu-ETP

A common material request for conductive busbar stock. Specify the governing standard, conductivity evidence, temper and mechanical requirements for the intended component.

02

C10200 · oxygen-free copper

An option to request when the component specification or joining process requires oxygen-free material. Confirm the exact designation and material condition before substitution.

03

Temper and product standard

Match harder or softer material conditions to rigidity, bending and processing needs. State ASTM B187/B187M or the relevant product standard and edition. For T2 or other drawing designations, include the governing material standard.

03 / APPLICATION GUIDE

From stock bar to electrical connection.

01

Switchgear & distribution equipment

Flat copper bars can be used as feedstock for main conductors and links. Specify the mounting layout, holes, bends and contact finish for the equipment design.

02

Transformer & equipment terminals

Connection bars and terminal links require defined contact areas and fastening geometry. Include the mating material, surface requirement and dimensional drawing.

03

Energy storage & power electronics

Rigid connection-bar inquiries may involve compact layouts and controlled interfaces. Provide the component drawing and insulation / clearance requirements; a plated surface does not define the system voltage rating.

04

Earthing & bonding connections

Copper bar can be specified for bonding or earthing components. Define section, hole pattern, mounting, finish and the applicable project requirements for the installation.

04 / PROCESSING & FINISH

Define the delivery condition.

01

Straight lengths & cut blanks

Provide the cut list, quantities and length tolerance. Identify stock blanks versus finished dimensions, including end squareness, burr removal and any machining allowance.

02

Hole, slot & bend requests

Send a dimensioned drawing with hole centres, slots, bend radii and datums. Requested fabrication is reviewed before it is included in the quotation.

03

Tin-plating requirements

Specify full or selected-area plating, required thickness and measurement locations, masking and any underlayer requirement. Agree the processing sequence for cutting, drilling, bending and plating.

04

Surface protection & identification

Protect contact faces from scratches and contamination. State identification and traceability needs, plus any approved marking locations away from functional surfaces.

05 / QUALITY & EXPORT PACKING

Material, dimensions & finish checks

  • Agree chemistry, material condition, conductivity evidence and dimensional inspection with batch identification.
  • For tin-plated bars, request the agreed coating-thickness, coverage and adhesion evidence with defined methods and acceptance criteria.
  • List material reports, conformity documents and any third-party or environmental-compliance evidence required by the order; availability is confirmed.

Packing & delivery preparation

  • Discuss interleaving, edge guards, supported bundles and cases; keep contact faces and plated surfaces separated from abrasive straps.
  • Provide the destination, maximum package weight, unloading method and applicable wood-packaging requirements.
  • Store dry, supported and clean; preserve identification and use handling that protects the specified finish.
TELL US WHAT YOU NEED

Bare or tinned? Bring the drawing into the conversation.

Send the section, length, preferred finish and quantity. For plated or fabricated parts, add the drawing and coating requirements you already know; remaining details can be clarified in the quotation.

Request a busbar quotation

Copper busbar buying questions

Can you supply both bare and tin-plated copper busbars?+

Yes. Specify the required finish with your dimensions and quantity. For tin plating, include coating thickness, coverage and any inspection requirements, or ask to clarify them during quotation.

Does tin plating automatically increase the current rating?+

No universal increase should be assumed. Finish selection must suit the connection and environment; current capability is assessed for the complete electrical assembly and its thermal conditions.

What should a drawing for a plated part include?+

Include the finished dimensions, datums, holes, bends, contact faces and masking requirements. State whether machining and dimensional acceptance occur before or after plating, and how the coating is inspected.